Antonio Nino Diaz c3cf06f1a3 Standardise header guards across codebase
All identifiers, regardless of use, that start with two underscores are
reserved. This means they can't be used in header guards.

The style that this project is now to use the full name of the file in
capital letters followed by 'H'. For example, for a file called
"uart_example.h", the header guard is UART_EXAMPLE_H.

The exceptions are files that are imported from other projects:

- CryptoCell driver
- dt-bindings folders
- zlib headers

Change-Id: I50561bf6c88b491ec440d0c8385c74650f3c106e
Signed-off-by: Antonio Nino Diaz <antonio.ninodiaz@arm.com>
2018-11-08 10:20:19 +00:00
dp-arm 82cb2c1ad9 Use SPDX license identifiers
To make software license auditing simpler, use SPDX[0] license
identifiers instead of duplicating the license text in every file.

NOTE: Files that have been imported by FreeBSD have not been modified.

[0]: https://spdx.org/

Change-Id: I80a00e1f641b8cc075ca5a95b10607ed9ed8761a
Signed-off-by: dp-arm <dimitris.papastamos@arm.com>
2017-05-03 09:39:28 +01:00
Sandrine Bailleux 543128771c Bug fix in the SP804 dual timer driver
The generic delay timer driver expects a pointer to a timer_ops_t
structure containing the specific timer driver information. It
doesn't make a copy of the structure, instead it just keeps the
pointer. Therefore, this pointer must remain valid over time.

The SP804 driver doesn't satisfy this requirement. The
sp804_timer_init() macro creates a temporary instanciation of the
timer_ops_t structure on the fly and passes it to the generic
delay timer. When this temporary instanciation gets deallocated,
the generic delay timer is left with a pointer to invalid data.

This patch fixes this bug by statically allocating the SP804
timer_ops_t structure.

Change-Id: I8fbf75907583aef06701e3fd9fabe0b2c9bc95bf
2015-09-28 16:33:00 +01:00
Ryan Harkin cc58b2d0f5 Add SP804 delay timer driver
Add a delay timer driver for the ARM SP804 dual timer.

This driver only uses the first timer, called timer 1 in the
SP804 Technical Reference Manual (ARM DDI 0271D).

To use this driver, the BSP must provide three constants:

*   The base address of the SP804 dual timer
*   The clock multiplier
*   The clock divider

The BSP is responsible for calling sp804_timer_init(). The SP804
driver instantiates a constant timer_ops_t and calls the generic
timer_init().

Change-Id: I49ba0a52bdf6072f403d1d0a20e305151d4bc086
Co-authored-by: Dan Handley <dan.handley@arm.com>