Juan Castillo 8dadabd288 Fix potential deadlock in PL011 init function
The PL011 initialization function disables the UART, flushes the FIFO
and waits for the current character to be transmitted before applying
the configuration and enabling the UART. This waiting might result in
a deadlock if the FIFO is disabled while another CPU is printing a
message since the flush of FIFO will never finish.

This patch fixes the problem by removing the flush operation and the
loop for last character completion from the initialization function.
The UART is disabled, configured and enabled again.

Change-Id: I1ca0b6bd9f352c12856f10f174a9f6eaca3ab4ea
2016-02-24 10:05:11 +00:00
..
pl011_console.S Fix potential deadlock in PL011 init function 2016-02-24 10:05:11 +00:00