plat: xilinx: zynqmp: Configure counter frequency during initialization
Counter frequency for generic timer of Arm-A53 based Application Processing Unit(APU) is not configuring in case if First Stage Boot Loader(FSBL) does not initialize counter frequency. This happens when FSBL is running from Arm-R5 based Real-time Processing Unit(RPU). Because of that generic timer driver functionality is not working. So configure counter frequency during initialization. Signed-off-by: Rajan Vaja <rajan.vaja@xilinx.com> Change-Id: Icfccd59d7d2340fba25ebfb2ef6a813af4290896
This commit is contained in:
parent
89a05821ec
commit
9f0ddae317
|
@ -350,10 +350,19 @@ unsigned int zynqmp_get_bootmode(void)
|
||||||
|
|
||||||
void zynqmp_config_setup(void)
|
void zynqmp_config_setup(void)
|
||||||
{
|
{
|
||||||
|
uint64_t counter_freq;
|
||||||
|
|
||||||
/* Configure IPI data for ZynqMP */
|
/* Configure IPI data for ZynqMP */
|
||||||
zynqmp_ipi_config_table_init();
|
zynqmp_ipi_config_table_init();
|
||||||
|
|
||||||
zynqmp_print_platform_name();
|
zynqmp_print_platform_name();
|
||||||
|
|
||||||
|
/* Configure counter frequency */
|
||||||
|
counter_freq = read_cntfrq_el0();
|
||||||
|
if (counter_freq == ZYNQMP_DEFAULT_COUNTER_FREQ) {
|
||||||
|
write_cntfrq_el0(plat_get_syscnt_freq2());
|
||||||
|
}
|
||||||
|
|
||||||
generic_delay_timer_init();
|
generic_delay_timer_init();
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
|
@ -17,6 +17,9 @@
|
||||||
|
|
||||||
#define ZYNQMP_CONSOLE_IS(con) (ZYNQMP_CONSOLE_ID_ ## con == ZYNQMP_CONSOLE)
|
#define ZYNQMP_CONSOLE_IS(con) (ZYNQMP_CONSOLE_ID_ ## con == ZYNQMP_CONSOLE)
|
||||||
|
|
||||||
|
/* Default counter frequency */
|
||||||
|
#define ZYNQMP_DEFAULT_COUNTER_FREQ 0U
|
||||||
|
|
||||||
/* Firmware Image Package */
|
/* Firmware Image Package */
|
||||||
#define ZYNQMP_PRIMARY_CPU 0
|
#define ZYNQMP_PRIMARY_CPU 0
|
||||||
|
|
||||||
|
|
Loading…