Increased BL2 maximum size when CoT descriptors are placed
in device tree.
Signed-off-by: Manish V Badarkhe <Manish.Badarkhe@arm.com>
Change-Id: I6466d2841e189e7f15eb4f1a8db070542893cb5b
Implemented a parser which populates the properties of
the CoT descriptors as per the binding document [1].
'COT_DESC_IN_DTB' build option is disabled by default and can
be enabled in future for all Arm platforms by making necessary
changes in the memory map.
Currently, this parser is tested only for FVP platform.
[1]:
https://trustedfirmware-a.readthedocs.io/en/latest/components/cot-binding.html
Change-Id: I2f911206087a1a2942aa728de151d2ac269d27cc
Signed-off-by: Manish V Badarkhe <Manish.Badarkhe@arm.com>
The size of debug binaries of SCP has increased beyond the current
limit of 80kB set in platform. Hence, increase it to 128kB.
Change-Id: I5dbcf87f8fb35672b39abdb942c0691fb339444a
Signed-off-by: Usama Arif <usama.arif@arm.com>
UUID's in the device tree files were stored in little endian. So
to keep all entries in these files RFC 4122 compliant, store them in
big endian then convert it to little endian when they are read so they
can be used in the UUID data structure.
Signed-off-by: Ruari Phipps <ruari.phipps@arm.com>
Change-Id: I5674159b82b245104381df10a4e3291160d9b3b5
At the moment BL31 dynamically discovers the CPU topology of an FPGA
system at runtime, but does not export it to the non-secure world.
Any BL33 user would typically looks at the devicetree to learn about
existing CPUs.
This patch exports a minimum /cpus node in a devicetree to satisfy
the binding. This means that no cpumaps or caches are described.
This could be added later if needed.
An existing /cpus node in the DT will make the code bail out with a
message.
Signed-off-by: Javier Almansa Sobrino <javier.almansasobrino@arm.com>
Change-Id: I589a2b3412411a3660134bdcef3a65e8200e1d7e
This patch adds dependencies to the generated configuration
files that are included in the FIP. This fixes occasional
build errors that occur when the FIP happens to be built first.
Change-Id: I5a2bf724ba3aee13954403b141f2f19b4fd51d1b
Signed-off-by: Anders Dellien <anders.dellien@arm.com>
In the case of Juno AArch32, platform security configuration
gets done from both BL2 and SP_MIN(BL32) components when
JUNO_AARCH32_EL3_RUNTIME and RESET_TO_SP_MIN build options
are set.
Fix is provided to avoid Platform security configuration from
SP_MIN when it is already done in BL2.
Signed-off-by: Manish V Badarkhe <Manish.Badarkhe@arm.com>
Change-Id: I702e91dacb4cdd2d10e339ddeaea91289bef3229
Using the Fconf, register base address of the various nv-counters
(currently, trusted, non-trusted nv-counters) are moved to the
device tree and retrieved during run-time. This feature is
enabled using the build option COT_DESC_IN_DTB.
Signed-off-by: Manish V Badarkhe <Manish.Badarkhe@arm.com>
Change-Id: I236f532e63cea63b179f60892cb406fc05cd5830
Allocated 512-959 SPI numbers for remote n1sdp chip and same has been
referenced for GIC routing table.
Change-Id: Id79ea493fd665ed93fe9644a59e363ec10441098
Signed-off-by: Sayanta Pattanayak <sayanta.pattanayak@arm.com>
Add information about the third partition so it can be loaded into SPM
when running the tests
Signed-off-by: Ruari Phipps <ruari.phipps@arm.com>
Change-Id: I5544e88df391ef294ddf6b5750d468d3e74892b1
In case of AT speculative workaround applied, page table walk
is disabled for lower ELs (EL1 and EL0) in EL3.
Hence added a wrapper function which temporarily enables page
table walk to execute AT instruction for lower ELs and then
disables page table walk.
Execute AT instructions directly for lower ELs (EL1 and EL0)
assuming page table walk is enabled always when AT speculative
workaround is not applied.
Change-Id: I4ad4c0bcbb761448af257e9f72ae979473c0dde8
Signed-off-by: Manish V Badarkhe <Manish.Badarkhe@arm.com>
Implemented platform functions to retrieve the soc-id information
for juno platform
Change-Id: Ie677120710b45e202a2d63a954459ece8a64b353
Signed-off-by: Manish V Badarkhe <Manish.Badarkhe@arm.com>
Implemented platform functions to retrieve the soc-id information
for FVP platform.
Change-Id: Id3df02ab290a210310e8d34ec9d706a59d817517
Signed-off-by: Manish V Badarkhe <Manish.Badarkhe@arm.com>
Removed common code for soc-id feature which is applicable
for all arm platforms.
In subsequent patches, added a platform based functions
for FVP and Juno to retrieve the soc-id information.
Change-Id: Idb632a935758a6caff2ca03a6eab8f663da8a93a
Signed-off-by: Manish V Badarkhe <Manish.Badarkhe@arm.com>
SP804 TIMER is not platform specific, and current code base adds
multiple defines to use this driver. Like FVP_USE_SP804_TIMER and
FVP_VE_USE_SP804_TIMER.
This patch removes platform specific build flag and adds generic
flag `USE_SP804_TIMER` to be set to 1 by platform if needed.
Change-Id: I5ab792c189885fd1b98ddd187f3a38ebdd0baba2
Signed-off-by: Madhukar Pappireddy <madhukar.pappireddy@arm.com>
* changes:
SPM: Add owner field to cactus secure partitions
SPM: Alter sp_gen.mk entry depending on owner of partition
plat/arm: enable support for Plat owned SPs
For supporting dualroot CoT for Secure Partitions a new optional field
"owner" is introduced which will be used to sign the SP with
corresponding signing domain. To demonstrate its usage, this patch adds
owners to cactus Secure Partitions.
Signed-off-by: Ruari Phipps <ruari.phipps@arm.com>
Change-Id: I7b760580355fc92edf5402cecc38c38125dc1cae
For Arm platforms SPs are loaded by parsing tb_fw_config.dts and
adding them to SP structure sequentially, which in-turn is appended to
loadable image list.
With recently introduced dualroot CoT for SPs where they are owned
either by SiP or by Platform. SiP owned SPs index starts at SP_PKG1_ID
and Plat owned SPs index starts at SP_PKG5_ID. As the start index of SP
depends on the owner, there should be a mechanism to parse owner of a SP
and put it at the correct index in SP structure.
This patch adds support for parsing a new optional field "owner" and
based on it put SP details(UUID & Load-address) at the correct index in
SP structure.
Change-Id: Ibd255b60d5c45023cc7fdb10971bef6626cb560b
Signed-off-by: Manish Pandey <manish.pandey2@arm.com>
This resolves MISRA defects such as:
plat/common/plat_bl1_common.c:63:[MISRA C-2012 Rule 14.4 (required)]
The condition expression "1" does not have an essentially boolean type.
Change-Id: I679411980ad661191fbc834a44a5eca5494fd0e2
Signed-off-by: Jimmy Brisson <jimmy.brisson@arm.com>
There was a collision between the name of the typedef in the CASSERT and
something else, so we make the name of the typedef unique to the
invocation of DEFFINE_SVC_UUID2 by appending the name that's passed into
the macro. This eliminates the following MISRA violation:
bl1/bl1_main.c:233:[MISRA C-2012 Rule 5.6 (required)] Identifier
"invalid_svc_uuid" is already used to represent a typedef.
This also resolves MISRA rule 5.9.
These renamings are as follows:
* tzram -> secram. This matches the function call name as it has
sec_mem in it's name
* fw_config_base -> config_base. This file does not mess with
hw_conig, so there's little chance of confusion
Change-Id: I8734ba0956140c8e29b89d0596d10d61a6ef351e
Signed-off-by: Jimmy Brisson <jimmy.brisson@arm.com>
BL31 binary size is aligned to 4KB because of the
code in include\plat\arm\common\arm_reclaim_init.ld.S:
__INIT_CODE_UNALIGNED__ = .;
. = ALIGN(PAGE_SIZE);
__INIT_CODE_END__ = .;
with all the zero data after the last instruction of
BL31 code to the end of the page.
This causes increase in size of BL31 binary stored in FIP
and its loading time by BL2.
This patch reduces the size of BL31 image by moving
page alignment from __INIT_CODE_END__ to __STACKS_END__
which also increases the stack size for secondary CPUs.
Change-Id: Ie2ec503fc774c22c12ec506d74fd3ef2b0b183a9
Signed-off-by: Alexei Fedorov <Alexei.Fedorov@arm.com>
Currently only single signing domain is supported for SP packages but
there is plan to support dual signing domains if CoT is dualroot.
SP_CONTENT_CERT_ID is the certificate file which is currently generated
and signed with trusted world key which in-turn is derived from Silicon
provider RoT key.
To allow dual signing domain for SP packages, other certificate file
will be derived from Platform owned RoT key.
This patch renames "SP_CONTENT_CERT_ID" to "SIP_SP_CONTENT_CERT_ID" and
does other related changes.
Signed-off-by: Manish Pandey <manish.pandey2@arm.com>
Change-Id: I0bc445a3ab257e2dac03faa64f46e36a9fed5e93
Following merge of patchset [1] the spm_mm_boot_info_t structure is
included in few platform files unconditionally even when SPM_MM option
is disabled.
[1] https://review.trustedfirmware.org/c/TF-A/trusted-firmware-a/+/2647
Signed-off-by: Olivier Deprez <olivier.deprez@arm.com>
Change-Id: I68bc034c9348b5d9bcfd2e5217b781df5ad1b369
The command line for BL33 payloads is typically taken from the DTB. On
"normal" systems the bootloader will put the right version in there, but
we typically don't use one on the FPGAs.
To avoid editing (and possibly re-packaging) the DTB for every change in
the command line, try to read it from some "magic" memory location
instead. It can be easily placed there by the tool that uploads the
other payloads to the FPGA's memory. BL31 will then replace the existing
command line in the DTB with that new string.
To avoid reading garbage, check the memory location for containing a
magic value. This is conveniently chosen to be a simple ASCII string, so
it can just preceed the actual command line in a text file:
--------------------------------
CMD:console=ttyAMA0,38400n8 debug loglevel=8
--------------------------------
Change-Id: I5923a80332c9fac3b4afd1a6aaa321233d0f60da
Signed-off-by: Andre Przywara <andre.przywara@arm.com>
Provide manifest and build options to boot OP-TEE as a
guest S-EL1 Secure Partition on top of Hafnium in S-EL2.
Increase ARM_SP_MAX_SIZE to cope with OP-TEE debug build image.
Signed-off-by: Olivier Deprez <olivier.deprez@arm.com>
Change-Id: Idd2686fa689a78fe2d05ed92b1d23c65e2edd4cb
This patch fixes a bug where wrong panic was caused when the number
of SP was same as max limit.
Signed-off-by: Manish Pandey <manish.pandey2@arm.com>
Change-Id: I9ace62d8d5bcdc410eeacdd9d33d55a7be5fcc8e
Currently, soc-revision information is not available for arm
platforms hence disabled 'SMCCC_ARCH_SOC_ID' feature for all arm
platforms.
Change-Id: I1ab878c6a4c8fecfff63bc6dde83e3ecefe20279
Signed-off-by: Manish V Badarkhe <Manish.Badarkhe@arm.com>
SPM(BL32) and hafnium(BL33) expect their manifest base address in x0
register, which is updated during BL2 stage by parsing fw_config.
In case of RESET_TO_BL31 it has to be updated while populating
entry point information.
Signed-off-by: Manish Pandey <manish.pandey2@arm.com>
Change-Id: I6f4a97f3405029bd6ba25f0935e2d1f74bb95517
As secondary cores show up, they populate an array to
announce themselves so plat_core_pos_by_mpidr() can
return an invalid COREID code for any non-existing
MPIDR that it is queried about.
The Power Domain Tree Description is populated with
a topology based on the maximum harcoded values.
Signed-off-by: Javier Almansa Sobrino <javier.almansasobrino@arm.com>
Change-Id: I8fd64761a2296714ce0f37c46544f3e6f13b5f61
In BL2, fw_config's population happened before the cache gets
enabled.
Hence to boost the performance, moved fw_config's population
after cache gets enabled (i.e. after MMU gets enabled).
Signed-off-by: Manish V Badarkhe <Manish.Badarkhe@arm.com>
Change-Id: I2e75cabd76b1cb7a660f6b72f409ab40d2877284
Updated the function 'set_fw_config_info' to make it generic
by doing below changes:
1. Rename function name from 'set_fw_config_info' to 'set_config_info'
2. Take image_id as an argument so that this function can set any
config information.
Signed-off-by: Manish V Badarkhe <Manish.Badarkhe@arm.com>
Change-Id: Icf29e19d3e9996d8154d84dbbbc76712fab0f0c1
Update the data type of the member 'config_max_size' present in the
structure 'dyn_cfg_dtb_info_t' to uint32_t.
This change is being done so that dyn_cfg_dtb_info_t and image_info
structure should use same data type for maximum size.
Change-Id: I9b5927a47eb8351bbf3664b8b1e047ae1ae5a260
Signed-off-by: Manish V Badarkhe <Manish.Badarkhe@arm.com>
Currently, the need for firmware update is being checked twice
in the code hence modifications are done to do this check only
once and set the global variable.
Then this global variable helps to decide whether to go for
normal boot or firmware update flow.
Change-Id: I8469284555a8039786f34670f9dc4830f87aecc1
Signed-off-by: Manish V Badarkhe <Manish.Badarkhe@arm.com>
Renamed node for trusted boot fw config from 'plat_arm_bl2' to
'tb_fw-config'.
Change-Id: I2e16b6f4d272292ec1855daafd014e851436dd9b